IPT 5581-IPT-96 6in Self-Priming Full Trash Pump (60000 GPH, Honda GX660)
$3,999.00
The IPT 5581-IPT-96 Self-Priming Full Trash Pump delivers up to 60,000 GPH (1,000 GPM) through 6-inch ports and handles solids up to 3 inches. Powered by a 24 HP Honda GX V-Twin engine and mounted on a DOT-approved trailer, it is ideal for construction dewatering, flood control, municipal bypass, and industrial pumping applications.
In Stock
Description
IPT 5581-IPT-96 6in Self-Priming Full Trash Pump (60,000 GPH, Honda GX660/GX690)
The IPT 5581-IPT-96 Self-Priming Full Trash Pump is a heavy-duty 6-inch trailer-mounted trash pump engineered for high-volume dewatering, flood control, municipal bypass pumping, mining operations, and large-scale construction projects. Powered by a commercial-grade Honda GX V-Twin engine (660cc class), this industrial pump delivers an impressive 60,000 GPH (1,000 GPM) flow rate while handling solids up to 3 inches in diameter.
Designed for demanding job sites, the pump features a self-priming centrifugal system capable of lifting water up to 20 feet, heavy-duty cast iron and aluminum construction, a stainless-steel trash impeller, and a silicon carbide mechanical seal for exceptional durability. Its patented slide-out pump housing allows quick cleaning and maintenance without disconnecting hoses, reducing downtime in critical pumping operations. Mounted on a DOT-approved trailer with electric start and integrated tachometer/hour meter, the IPT 5581-IPT-96 provides maximum mobility and performance for contractors, municipalities, emergency response teams, and industrial operators requiring reliable high-capacity pumping.
Key Features
- Massive 60,000 GPH (1,000 GPM) pumping capacity
- Commercial-grade Honda GX V-Twin engine
- Handles solids and debris up to 3 inches
- Self-priming up to 20 feet
- Electric start with tachometer/hour meter
- Heavy-duty cast aluminum and cast iron construction
- Stainless-steel trash impeller
- Silicon carbide mechanical seal for abrasive environments
- Patented slide-out housing for fast cleanout and servicing
- DOT-approved trailer for easy transportation
- Built for continuous-duty industrial operation
- Ideal for large-scale dewatering and emergency response
Applications
- Construction site dewatering
- Flood and stormwater control
- Municipal bypass pumping
- Wastewater and sewage transfer
- Mining and quarry operations
- Agricultural water management
- Industrial water transfer
- Disaster recovery and emergency response
- Pipeline and infrastructure projects
- Large-scale excavation work
For safety and compliance context relevant to this category, see DOE pumping systems guidance. Related: more Engine Driven Pumps.
IPT 5581-IPT-96 6in Self-Priming Full Trash Pump (60000 GPH, Honda GX660): Buying Considerations
The IPT 5581-IPT-96 Self-Priming Full Trash Pump delivers up to 60,000 GPH (1,000 GPM) through 6-inch ports and handles solids up to 3 inches. Powered by a 24 HP Honda GX V-Twin engine and mounted on a DOT-approved trailer, it is ideal for construction dewatering, flood control, municipal bypass, and industrial pumping applications.
Before ordering the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump (60000 GPH, Honda GX660) from IPT, review the points below against your actual site conditions and workload. Published specifications describe the equipment under test conditions, and real-world performance depends on how closely your application matches those conditions. Buyers in the United States, Canada, and Asia should also confirm local voltage and frequency requirements, applicable safety or emissions standards, and freight or import logistics for the destination before finalizing an order.
What to Check Before You Buy
- Define required flow and total dynamic head at the discharge point – engine-driven pumps are commonly undersized when only flow rate is considered.
- Check suction lift, priming method, and maximum solids size the pump can handle without clogging.
- Verify fuel type and runtime requirements match the application, especially for extended dewatering or irrigation jobs.
- Confirm hose/fitting size matches the pump's rated port size to avoid unnecessary friction loss.
How much reserve capacity should an engine-driven pump have over the calculated requirement?
A reasonable margin accounts for pipe friction losses, fitting losses, and any future demand growth – undersizing based purely on a theoretical flow calculation without real-world losses is a common reason pumps underperform once installed.
For sizing help across the full Engine Driven Pumps category, compare specifications side by side before committing to a specific model, and confirm current pricing, availability, and freight details for your location. Keep the supplier data sheet and any acceptance criteria on record for future maintenance and replacement decisions.
Total Cost of Ownership
The purchase price of the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump (60000 GPH, Honda GX660) is only part of the real cost of owning this equipment. Factor in routine maintenance parts, consumables specific to the Engine Driven Pumps category, fuel or energy use over the equipment’s service life, and the cost of downtime if a failure happens during a critical job. Equipment with a lower purchase price but weaker local parts availability or a shorter warranty period can end up costing more over three to five years than a model with a higher upfront price and stronger support.
Warranty and Support
Confirm the specific warranty terms IPT offers on this model, including coverage length, what is and is not covered (wear parts are frequently excluded), and whether the warranty is transferable if the equipment is resold. Check whether authorized service is available in your region before an issue comes up, rather than after – parts and qualified technician availability varies significantly by location and can be the deciding factor between two otherwise comparable machines.
Keep the original purchase documentation, serial number, and any commissioning or acceptance records together – this documentation is typically required to make a warranty claim and simplifies any future resale or insurance process.
Looking for the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump? This model is a popular choice among buyers who need dependable performance from the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump. Our team frequently recommends the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump for its balance of build quality, reliability, and value in daily industrial use.
Customers consistently rate the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump highly for its consistent output and ease of maintenance. If you’re comparing options, the IPT 5581-IPT-96 6in Self-Priming Full Trash Pump stands out as a reliable, well-supported choice backed by manufacturer warranty.
| Specification | Details |
|---|---|
| Model | 5581-IPT-96 |
| Brand | IPT Pumps |
| Pump Type | Self-Priming Full Trash Pump |
| Engine Model | Honda GX690 V-Twin |
| Engine Type | 4-Stroke OHV Gasoline Engine |
| Engine Displacement | 660 cc |
| Engine Power | 24 HP |
| Fuel Type | Gasoline |
| Maximum Flow Rate | 60,000 GPH (1,000 GPM) |
| Inlet Size | 6 in |
| Outlet Size | 6 in |
| Maximum Solids Handling | 3 in (76 mm) |
| Maximum Pressure | 40–43 PSI |
| Maximum Head | 98 ft |
| Maximum Suction Lift | 20 ft |
| Pump Housing | Cast Aluminum |
| Volute & Manifold | Cast Iron |
| Impeller Material | Stainless Steel |
| Mechanical Seal Silicon | Carbide |
| Priming Type | Self-Priming |
| Starting System | 12V Electric Start |
| Fuel Tank Capacity | 12 Gal |
| Runtime Up to | 6 Hours |
| Trailer Type | DOT-Approved Trailer |
| Dimensions (L × W × H) | 93 × 52 × 49 in |
| Weight | Approx. 800–1125 lbs |
| Warranty | 1-Year Pump / 3-Year Engine Limited Warranty |


Reviews